Vibrating-wire piezometer
Digital output, high waterproof performance

Product Introduction
Vibrating-wire piezometer
The vibrating‑wire piezometer is a pore‑water pressure measurement device based on the vibrating‑wire sensing principle. It is designed for long-term installation in soil, concrete dams, or foundations to monitor seepage pressures and water‑level fluctuations.
The sensor features a stainless‑steel construction and a thermally stable design, offering high accuracy, low drift, and excellent corrosion resistance. When paired with an intelligent data‑acquisition system, it enables remote calibration, fault diagnosis, and seamless integration with cloud platforms, making it widely used in hydraulic engineering, geological hazard monitoring, and geotechnical engineering applications.
keyword:
Vibrating-wire piezometer
Category:
Environmental Structure Monitoring
PRODUCT FEATURES
- Compact and highly sensitive: Featuring a compact design and a small footprint, it also delivers high output sensitivity, making it ideal for tight spaces.
- Long-lasting, stable, and reliable: The device features an all-stainless-steel construction and a high‑waterproof design, ensuring long-term stability and reliability when installed underground.
- Long-distance data transmission: It outputs a digital signal based on the vibrating‑string principle, offering strong anti‑interference performance and supporting longer‑distance signal transmission.
- Temperature Synchronization Correction: It can simultaneously measure the temperature at the installation location, providing an accurate temperature correction basis for pressure measurements.
TECHNICAL SPECIFICATIONS
| Technical Name | Technical Specifications |
| Measurement range | 0~350 kPa (0~700, 0~1000, 0~2000, 0~3000 optional) |
| Resolution | 0.025%FS |
| Fitting/End-Group Accuracy | 0.1%F.S / 0.5%F.S |
| Temperature measurement range | -40 ~ +80°C |
| Sensitivity | ±0.1°C |
| Temperature measurement accuracy | ±0.5° |
| Correction factor b | 0.10 KPa/°C |
| Water pressure resistance | Measurement range: 1.2 times |
| Insulation resistance | ≥50MΩ |
Note: Frequency modulus F=Hz²×10⁻³ |